Common faults
1. Leakage:
Possible causes: poor sealing, wear of the pump body, excessive rotor clearance.
2. Abnormal sound:
Possible causes: bearing damage, rotor eccentricity, impeller imbalance.
3. Excessive temperature:
Possible causes: excessive bearing friction, failure of magnetic transmission, poor sealing of the pump body.
4. Flow Reduction:
Possible causes: impeller wear, inlet clogging, pump body wear.
5. No liquid:
Possible causes: air leakage in the suction line, insufficient liquid volume in the pump, blockage in the pipe.
6. Insufficient head:
Possible causes: the conveying medium contains air, the impeller is damaged, the speed is not enough, and the liquid is heavy.
7. Shaft breakage:
Possible cause: Dry grinding of bearings due to dry running of the pump.
Solution:
1. Leakage:
Inspect and trim or replace the seals and worn parts of the pump body.
Adjust the rotor clearance to the appropriate range.
2. Abnormal sound:
Replace or clean worn, loose, contaminated bearings.
Adjust or replace eccentric, unbalanced rotors.
Repair or replace the impeller.
3. Excessive temperature:
Inspect and add lubricating oil to the bearing.
Adjust or replace the magnetic transmission section.
Trim or replace seals.
4. Flow Reduction:
Repair or replace worn impellers.
Clean up inlet blockages.
Trim or replace worn pump bodies.
5. No liquid:
Inspect and repair air leaks in the suction line.
Make sure the pump has enough liquid.
Clean the blockage in the tube.
6. Insufficient head:
Check and drain the air from the conveying medium.
Repair or replace damaged impellers.
Adjust the pump speed to the appropriate range.
7. axis break:
Avoid dry running of the pump, regularly inspect and replace worn parts.
The above treatment methods are for reference only, and should be operated according to the actual situation and instruction manual of the magnetic pump. If the fault cannot be eliminated, it is recommended to contact professional and technical personnel for maintenance.
Contact: NEIL
Phone: 86-18205509969
E-mail: 18205509969@139.com